Photometer Heads The quality of LMT photometer heads represents the highest level of technology worldwide Light-sensitive detectors
- Si-photoelements of excellent quality and longtime stability
- classified and selected for specific applications
- illuminance and photocurrent absolutely proportional
Relative spectral responsivity
- adapted to the spectral luminous efficiency V(λ) of the human eye (according to CIE, DIN)
- very fine V(λ)-approximation by partial filtering, error f'1 (CIE) resp. f'1 (DIN) ≤ 0.8 %
- fine V(λ)-approximation by full filtering, error f'1 (CIE) resp. f'1 (DIN) ≤ 2.5 %
- UV and IR response < 0.1 %
Directional response
- photometer heads for perpendicular light incidence
- cosine correction for measurement of illuminance by light incidence from different directions, error f2 (CIE, DIN) £ 1.5 %
- adapters and photometer heads for measurement of cylindrical (Ez) or semi-cylindrical (Esc) illuminance
Temperature dependence
- without thermostatic stabilization α0 < 0.1 %/K
- with thermostatic stabilization α0 < 0.01 %/K
Sensitivity
- measurement down to 0.00001 lx in combination with high precise LMT photocurrent amplifiers
Light sensitive surface
- light sensitive surfaces 5, 10, 15, 30 mm Ø, and user specified diameters
Special detectors
- photometer heads in splash-proof housing and defroster for outdoor installation
- V'(λ) detectors for scotopic vision
- Esy (photosynthesis) detectors
- Ebi (bilirubin dissociation) detectors
- blue/red detectors
- photometer heads with photomultipliers
Technical data and calibration
- individual test report for relative spectral responsivity
- individual test report for directional response
- specified errors acc. to DIN 5032 part 6 and 7 and CIE Publ. No. 69 (1987)
- LMT calibration certificate for illuminance respositivity, traceable to PTB calibrated standard, relative expanded measurement uncertainty incl. the
uncertainty of the Standard employed 0.8%
|